Steel Buildings

$25.00
Earthquake and Tsunami, Building Design, Pre-Disaster, Structural, Steel Buildings
The SAC-95-01 report, Steel Moment-Frame Connection Advisory No. 3 , was funded by the Federal Emergency Management Agency (FEMA) and the California Office...
In stock
+

Minimum quantity for "Steel Moment-Frame Connection Advisory No. 3" is 1.


$35.00
Steel Buildings, Pre-Disaster, Earthquake and Tsunami, Building Design, Structural
The SAC/BD-99/14, Simplified Loss Estimation for Pre-Northridge WSMF Buildings , was funded by the Federal Emergency Management Agency (FEMA) and the...
In stock
+

Minimum quantity for "Simplified Loss Estimation for Pre-Northridge WSMF Buildings" is 1.


$55.00
Earthquake and Tsunami, Building Design, Pre-Disaster, Steel Buildings, Structural
The SAC/BD-00/15, Simplified Design Models for Predicting the Seismic Performance of Steel Moment Frame Connection , was funded by the Federal Emergency...
In stock
+

Minimum quantity for "Simplified Design Models for Predicting the Seismic Performance of Steel Moment Frame Connection" is 1.


$35.00
Earthquake and Tsunami, Building Design, Pre-Disaster, Structural, Steel Buildings
The SAC/BD-96/01, Selected Results from the SAC Phase 1 Beam-Column Connection Pre-Test Analyses , was funded by the Federal Emergency Management Agency...
In stock
+

Minimum quantity for "Selected Results from the SAC Phase 1 Beam-Column Connection Pre-Test Analyses" is 1.


$40.00
Earthquake and Tsunami, Building Design, Pre-Disaster, Structural, Steel Buildings
The SAC/BD-96/03, Selected Documents from the U.S.-Japan Workshop on Steel Fracture Issues , was funded by the Federal Emergency Management Agency (FEMA)...
In stock
+

Minimum quantity for "Selected Documents from the U.S.-Japan Workshop on Steel Fracture Issues" is 1.


$40.00
Building Design, Earthquake and Tsunami, Pre-Disaster, Steel Buildings, Structural
The SAC/BD-99/16, Seismic Performance of 3 and 9 Story Partially Restrained Moment Frame Buildings , was funded by the Federal Emergency Management Agency...
In stock
+

Minimum quantity for "Seismic Performance of 3 and 9 Story Partially Restrained Moment Frame Buildings" is 1.


$35.00
Structural, Steel Buildings, Pre-Disaster, Earthquake and Tsunami, Building Design
The SAC CD01-01, Seismic Design Criteria for Steel Moment-Frame Structures , contains the following reports in fully-indexed PDF format: FEMA-350,...
In stock
+

Minimum quantity for "Seismic Design Criteria for Steel Moment-Frame Structures" is 1.


$100.00
Earthquake and Tsunami, Building Design, Pre-Disaster, Steel Buildings, Structural
The SAC CD01-02, SAC Steel Project, Regional Training Seminar , is a four-disk USB set contains video presentations (with visual aids) of the SAC Phase II...
In stock
+

Minimum quantity for "SAC Training Presentations" is 1.


$300.00
Pre-Disaster, Earthquake and Tsunami, Building Design, Steel Buildings, Structural
The SAC_CD01-03, SAC Steel Project, Background Documents , is a three-zip USB set contains the following 66 background documents, SAC/BD-96/01 through...
In stock
+

Minimum quantity for "SAC Steel Project, Background Documents" is 1.


$35.00
Structural, Steel Buildings, Pre-Disaster, Earthquake and Tsunami, Building Design
The SAC/BD-00/16, SAC Phase 2 Test Plan , was funded by the Federal Emergency Management Agency (FEMA) and the California Office of Emergency Services...
In stock
+

Minimum quantity for "SAC Phase 2 Test Plan" is 1.


$35.00
Structural, Steel Buildings, Pre-Disaster, Earthquake and Tsunami, Building Design
The SAC/BD-00/06, Round-Robin Testing of Ultrasonic Testing Technicians , was funded by the Federal Emergency Management Agency (FEMA) and the California...
In stock
+

Minimum quantity for "Round-Robin Testing of Ultrasonic Testing Technicians" is 1.


$55.00
Earthquake and Tsunami, Building Design, Pre-Disaster, Steel Buildings, Structural
The SAC/BD-99/22, Reliability-Based Seismic Performance Evaluation of Steel Frame Buildings Using Nonlinear Static Analysis Methods , was funded by the...
In stock
+

Minimum quantity for "Reliability-Based Seismic Performance Evaluation of Steel Frame Buildings Using Nonlinear Static Analysis Methods" is 1.